Powerware 6000 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Narzędzia Powerware 6000. Powerware 6000 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
powerware
®
9
Prestige Series
User’s Guide
4500/6000 VA
www.powerware.com
Przeglądanie stron 0
1 2 3 4 5 6 ... 91 92

Podsumowanie treści

Strona 1 - Prestige Series

powerware®9Prestige SeriesUser’s Guide4500/6000 VAwww.powerware.com

Strona 2 - European EMC Statement

Introduction2Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comUPS Model and Battery ConfigurationsThis UPS is designed t

Strona 3 - UPS QUICK INSTALLATION

Introduction3Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com3. Add all of the resultant VA ratings together to obtain

Strona 4 - UPS Quick Installation

Introduction4Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comSpecial SymbolsThe following common symbols may be found o

Strona 5

5Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comCHAPTER 2SAFETY WARNINGSIMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRU

Strona 6

Safety Warnings6Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comPlease note that the output sockets on the UPS are elec

Strona 7 - TABLE OF CONTENTS

Safety Warnings7Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comNetledningen må ikke fjernes og stikket må ikke trækkes

Strona 8 - Table of Contents

Safety Warnings8Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comNooit batterijen in het vuur gooien. De batterijen kunn

Strona 9 - INTRODUCTION

Safety Warnings9Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comTärkeitä turvaohjeitaTÄRKEITÄ TURVAOHJEITA - SUOMISÄILY

Strona 10 - Load Requirements

Safety Warnings10Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comTämän laitteen mukana ei toimiteta lähdön ylivirtasuoj

Strona 11

Safety Warnings11Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comLa prise secteur doit se trouver à moins de 2 m du mat

Strona 12 - Special Symbols

FCC StatementThe Powerware 9 Prestige Series UPS configurations vary. Some configurations may or may not be classified by theFederal Communications Co

Strona 13 - SAFETY WARNINGS

Safety Warnings12Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comBatteriennie öffnen oder anderweitig beschädigen.Derda

Strona 14 - Sikkerhedsanvisninger

Safety Warnings13Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com

Strona 15 - Safety Warnings

Safety Warnings14Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comAvvisi di sicurezzaIMPORTANTI ISTRUZIONI DI SICUREZZAC

Strona 16

Safety Warnings15Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comquesto gruppo statico di continuità contiene una fonte

Strona 17 - Tärkeitä turvaohjeita

Safety Warnings16Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comViktig SikkerhetsinformasionFARLIGDenne UPS’en innehol

Strona 18 - Consignes de sécurité

Safety Warnings17Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comRegulamentos de SegurançaINSTRUÇÕES DE SEGURANÇA IMPOR

Strona 19 - Sicherheitswarnungen

Safety Warnings18Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comPara sistemas Bypass com saídas conectadas, a proteção

Strona 20

Safety Warnings19Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comДля снижения опасности пожара или поражения электричес

Strona 21

Safety Warnings20Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comAdvertencias de SeguridadINSTRUCCIONES DE SEGURIDAD IM

Strona 22 - Avvisi di sicurezza

Safety Warnings21Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comTenga en cuenta que los receptáculos de salida del SIE

Strona 23

UPS QUICK INSTALLATIONCAUTIONRead the safety instructions beginning on page 5 before installing the UPS.1234

Strona 24 - Viktig Sikkerhetsinformasion

Safety Warnings22Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comTa aldrig bort nätsladden när UPS-enheten är påslagen.

Strona 25 - Regulamentos de Segurança

23Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comCHAPTER 3INSTALLATIONThe following sections describe UPS storage requ

Strona 26

Installation24Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comSelecting an Installation OptionYou are now ready to inst

Strona 27

Installation25Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comNOTE Do not connect more than six standard battery cabine

Strona 28 - Advertencias de Seguridad

Installation26Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comBattery CircuitBreakerBatteryCabinetBatteryCabinetBattery

Strona 29 - Säkerhetsföreskrifter

Installation27Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com5. If additional battery cabinets are to be used, plug th

Strona 30

Installation28Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com9. If you are using a Remote Emergency Power-Off (REPO)sw

Strona 31 - INSTALLATION

Installation29Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comMounting HolesPlug/ReceptaclePPU ConnectorThree Foot Cord

Strona 32 - Powerware

Installation30Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comPPUBatteryCabinetsAir VentsBattery CabinetsPPUFigure 7. C

Strona 33

Installation31Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comBatteryCircuitBreakerBatteryConnectorPPU Battery Cabinets

Strona 34

UPS Quick Installation567

Strona 35 - Selector

Installation32Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comVoltageSelectorSwitchFigure 9. Voltage Selector Switch5.

Strona 36 - REPO Installation

Installation33Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com6. Hardwire the input (TB1-1 through TB1-3) and outputter

Strona 37 - UPS Hardwired Installation

Installation34Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comGroundTB1TB2GroundLine 1Input ConnectionOutput Connection

Strona 38 - OFF (O) position

Installation35Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com9. If you are using a REPO switch, hardwire the terminal

Strona 39

Installation36Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comUPS StartupTo start up the UPS:1. Verify the input breake

Strona 40

Installation37Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comThe indicator remains lit and the Self Test indicator tur

Strona 41

Installation38Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comPPDMPPUBattery CabinetsAirVentsFigure 12. UPS with PPDMNO

Strona 42

Installation39Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comUtility Input ToPPDM (Cord Provided)Input BreakerBypass S

Strona 43

Installation40Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comPPU Battery CabinetsCircuitBreakerBatteryConnectorBreaker

Strona 44 - UPS Startup

Installation41Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com4. Select the correct UPS output voltage according to the

Strona 45

34UPS with Optional PPDM Quick InstallationUPS WITH OPTIONAL PPDM QUICK INSTALLATIONCAUTIONRead the safety instructions beginning on page 5 before ins

Strona 46 - Figure 12. UPS with PPDM

Installation42Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comVoltageSelectorSwitchFigure 15. Voltage Selector Switch5.

Strona 47

Installation43Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com8. Remove the screws on the PPDM rear panel with a Philli

Strona 48

Installation44Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com9. Hardwire the input (TB1) and output terminations (TB2)

Strona 49

Installation45Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comTB1Input ConnectionOutput ConnectionTB2NeutralBondingJump

Strona 50

Installation46Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com11. As part of the branch circuit that supplies this unit

Strona 51

Installation47Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comUPS with PPDM StartupTo start up the UPS:1. Verify the PP

Strona 52

Installation48Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com12. Press and hold the Output On button until you hear th

Strona 53

49Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comCHAPTER 4UPS OPERATIONThis chapter covers the operation of the UPS in

Strona 54

UPS Operation50Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comOperating ModesAfter you install and apply power to the

Strona 55 - UPS with PPDM Startup

UPS Operation51Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comBypass ModeThe indicator and the indicator illuminate si

Strona 56 - Troubleshooting Tips

UPS with Optional PPDM Quick Installation56789

Strona 57 - UPS OPERATION

UPS Operation52Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comWhen shutdown is imminent, the Self Test indicator flash

Strona 58 - Operating Modes

UPS Operation53Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comUPS ShutdownPerforming a UPS shutdown turns off the powe

Strona 59 - Battery Mode

UPS Operation54Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comUsing the PPDMThe PPDM provides continuous online power

Strona 60 - Battery Start

UPS Operation55Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com4. Remove the cord connections to the back of the PPU.5.

Strona 61 - Changing the Output Voltage

UPS Operation56Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comUse the following procedure to reinstall the PPU and tra

Strona 62 - Using the PPDM

UPS Operation57Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comVoltageSelectorSwitchFigure 25. Voltage Selector Switch4

Strona 63 - 7. Remove the PPU

UPS Operation58Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com

Strona 64

59Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comCHAPTER 5COMMUNICATIONThe UPS is equipped with a communications inter

Strona 65 - UPS Operation

Communication60Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comFront Panel Communications AccessBefore you access the f

Strona 66

Communication61Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comTo access the front panel communication options, perform

Strona 67 - COMMUNICATION

iPowerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comTABLE OF CONTENTS1 Introduction 1...

Strona 68 - Flashing

Communication62Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comUPS Serial Communications MenuWith the UPS Serial Commun

Strona 69 - Communication

Communication63Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comNOTE Catalog #, Serial #, and Version # are all identifi

Strona 70

Communication64Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comSelect the AS400 option if you are using OnliSafe softwa

Strona 71

Communication65Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comZ > Set Baud Rate allows you to select a new baud rat

Strona 72

Communication66Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comUPS Communications Interface PortIn addition to configur

Strona 73 - Power Management Software

Communication67Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comCommunications Mode Reference ChartThe following chart d

Strona 74

Communication68Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com

Strona 75

69Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comCHAPTER 6SPECIFICATIONSPrestige 6000 SpecificationsThe following mode

Strona 76

Specifications70Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comModel 4500 UPS (Nominal Operating Specifications)Output

Strona 77 - SPECIFICATIONS

Specifications71Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comTechnical SpecificationsInput Voltage Range 170 to 276

Strona 78 - Physical Specifications

Table of ContentsiiPowerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com5 Communication 59...

Strona 79 - Technical Specifications

Specifications72Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comElectrical Specifications for the Prestige 6000 with PP

Strona 80

Specifications73Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comPrestige 6000 PPDM Ratings with a Model 4500 UPSPPDM Mo

Strona 81

Specifications74Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com

Strona 82 - Specifications

75Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comCHAPTER 7TROUBLESHOOTINGThe Prestige UPS is designed for durable, aut

Strona 83 - TROUBLESHOOTING

Troubleshooting76Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comActionPossible CauseConditionRemote EmergencyPower-Off

Strona 84

Troubleshooting77Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comActionPossible CauseConditionBATTERYWeak battery while

Strona 85 - Silencing the Alarm

Troubleshooting78Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comService and SupportThe troubleshooting chart on page 7

Strona 86 - Service and Support

79Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comINDEXNumeric3Com Network Interfacefront panel configuration, 60LAN Co

Strona 87

Index80Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comControl KeysControl-C, 62Control-E, 63cord, power, 36, 47, 71Cus

Strona 88

Index81Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comMMain Menu, 62Maintenance Bypass featureSee also PowerPass Distr

Strona 89

1Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comCHAPTER 1INTRODUCTIONCongratulations on the purchase of your Powerware

Strona 90

Index82Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comREPO connectors, 26serial port, 26Polled Dump Mode, 63Power Mana

Strona 91

Index83Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.comtroubleshootingchart, 75tips, 48Uuninterruptible power system, 1

Strona 92

Index84Powerware®9 Prestige Series User’s Guide (4500/6000 VA) Rev H www.powerware.com

Powiązane modele: 4500