Powerware 208/120V Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Narzędzia Powerware 208/120V. Powerware 208/120V User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
Powerware Energy Management System (EMS)
Upgrade Kit (208/120V, 380/220V, 400/230V, 415/240V)
User’s Guide
®
Przeglądanie stron 0
1 2 3 4 5 6 ... 71 72

Podsumowanie treści

Strona 1 - User’s Guide

Powerware Energy Management System (EMS)Upgrade Kit (208/120V, 380/220V, 400/230V, 415/240V)User’s Guide®

Strona 2

INTRODUCTIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com4Consignes de sécuritéCONSIG

Strona 3 - Special Symbols

INTRODUCTIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com5SicherheitswarnungenWICHTIG

Strona 4

INTRODUCTIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com6Advertencias de SeguridadIN

Strona 5 - Table of Contents

EATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com7Chapter 2 InstallationThis section expl

Strona 6 - TABLE OF CONTENTS

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com8Checking the Parts ListVeri

Strona 7 - Chapter 1 Introduction

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com9Main input monitoring optio

Strona 8 - INTRODUCTION

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com10Installing the HardwareNOT

Strona 9 - SAVE THESE INSTRUCTIONS

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com113. Attach the mounting bra

Strona 10 - CONSERVER CES INSTRUCTIONS

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com128. If installing a right c

Strona 11 - AUFBEWAREN

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com13Electrical ConnectionsW A

Strona 12 - GUARDE ESTAS INSTRUCCIONES

Requesting a Declaration of ConformityUnits that are labeled with a CE mark comply with the following harmonized standards and EU directives:S Harmoni

Strona 13 - Chapter 2 Installation

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com143. Plan the wiring route f

Strona 14 - Checking the Parts List

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com15Table 4. Harness SizingHar

Strona 15 - Tools Required

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com164. Connect the circular co

Strona 16 - Installing the Hardware

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com17Figure 7. Panel Detail (EM

Strona 17 - Figure 3. Mounting Template

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com185. Main input monitoring o

Strona 18 - Figure 4. Conduit Box Option

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com196. 75A or 100A Split−Core

Strona 19 - C A U T I O N

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com209. Subfeed Accessory only.

Strona 20 - INSTALLATION

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com21C A U T I O NS Panel 1 vol

Strona 21 - Table 4. Harness Sizing

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com2213. Unoccupied three−phase

Strona 22

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com23NOTE Use wire taps ONLY o

Strona 23

Special SymbolsThe following are examples of symbols used on the UPS or accessories to alert you to importantinformation:RISK OF ELECTRIC SHOCK − Obse

Strona 24

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com2417. If installing communic

Strona 25

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com25Initial ConfigurationThis

Strona 26

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com26Initial System Configurati

Strona 27

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com275. Verify that meter and s

Strona 28

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com286. Click the EMS System Se

Strona 29

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com298. Optional. To prevent th

Strona 30 - Power LED

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com3011. Click the Feature Sett

Strona 31 - Initial Configuration

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com3115. To configure panels an

Strona 32 - Initial System Configuration

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com324. Configure the following

Strona 33

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com339. The selected breaker is

Strona 35

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com34Initial Panel and Breaker

Strona 36

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com3511. From the setup screen,

Strona 37 - Software Configuration Tool)

INSTALLATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com36Advanced Metering Installa

Strona 38

EATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com37Chapter 3 OperationThis chapter descri

Strona 39

OPERATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com38Control Panel FunctionsNOTE

Strona 40

OPERATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com39Display FunctionsThe LCD disp

Strona 41 - Installation."

OPERATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com40Menu MapThe following tables

Strona 42 - S Connect the Ethernet cable

OPERATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com41Table 7. Panel MetersScreen L

Strona 43 - Chapter 3 Operation

OPERATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com42Setup OptionsAccess to setup

Strona 44 - Control Panel Functions

OPERATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com43Control Panel ConfigurationNO

Strona 45 - EATON EMS−UGK

EATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.comiTable of Contents1 Introduction 1. . .

Strona 46 - Menu Map

OPERATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com444. On the PANEL CONFIG screen

Strona 47 - Table 8. Breaker Meters

OPERATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com454. On the PANEL CONFIG screen

Strona 48 - Setup Options

OPERATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com46Configuring Branch Circuit Br

Strona 49 - Control Panel Configuration

OPERATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com476. When the individual circui

Strona 50 - OPERATION

OPERATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com48Viewing Panel MetersNOTE Use

Strona 51

EATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com49Chapter 4 CommunicationThis section de

Strona 52

COMMUNICATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com50Installing Communication

Strona 53

COMMUNICATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com51Use the computer’s HyperT

Strona 54 - Viewing Breaker Meters

COMMUNICATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com52Control TerminalsThe cabl

Strona 55 - Chapter 4 Communication

COMMUNICATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com53Relay Output Contacts (Al

Strona 56 - Communication Options

TABLE OF CONTENTSEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.comii4 Communication 49. .

Strona 57 - X−Slot Card

COMMUNICATIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com54

Strona 58 - Control Terminals

EATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com55Chapter 5 MaintenanceKeep the area aro

Strona 59 - W A R N I N G

MAINTENANCEEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com56Rewiring and Reconfiguring

Strona 60 - COMMUNICATION

EATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com57Chapter 6 SpecificationsTable 12. Dime

Strona 61 - Chapter 5 Maintenance

SPECIFICATIONSEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com58Table 14. Electrical Inp

Strona 62 - A N G E R

SPECIFICATIONSEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com59Table 17. MeteringPanel

Strona 63 - Chapter 6 Specifications

SPECIFICATIONSEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com60

Strona 64 - 240 pixels)

EATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com61Chapter 7 TroubleshootingTypical Alarm

Strona 65 - Table 17. Metering

TROUBLESHOOTINGEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com62

Strona 66 - SPECIFICATIONS

EATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com63Chapter 8 WarrantyLimited Factory Warr

Strona 67 - Chapter 7 Troubleshooting

EATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com1Chapter 1 IntroductionEaton’s Powerware

Strona 68 - TROUBLESHOOTING

WARRANTYEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com64END−USER’S OBLIGATIONS: In or

Strona 70 - EATON Powerware

*1642017241*164201724 1

Strona 71

INTRODUCTIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com2The following options for t

Strona 72 - *1642017241*

INTRODUCTIONEATON Powerware® Energy Management System (EMS) Upgrade Kit User’s Guide S 164201724 Rev 1 www.powerware.com3Safety WarningsIMPORTANT SA

Powiązane modele: 400/230V | 415/240V | 380/220V |